32
炼油与化工
REFINING AND CHEMICAL INDUSTRY
合成氨装置冷冻系统的工艺优化调整
王静宇
(大庆石化公司化肥厂.黑龙江大庆163714)
摘要:文中分析了某化肥厂合或氮装置合成工段出现的生产间题,重点讨论了氨气压缩机105-J能力不足和合成气压缩机103-J能耗高的间题。采取了相应的技术措能,使合成系统的工况得到了明显的改善。
关键词:合成工段;105-J;103-J;功耗
中图分类号:TQ113.25
文献标识码:B
文章编号:16714962(2016)02003202
Process optimization and adjustment to refrigeration system of
syntheticammoniaplant
WangJingyu
(Chemical Fertilizer Plant of Daqing Petrochemical Company, Daqing 163714, China)
第27卷
Abstract: This paper analyzed production problems existed in synthetic section in the synthetic ammonia plant of a chemical fertilizer plant, and mainly discussed the problems of insufficient capacity of ammonia gas compressor 105J and high power consumption of synthesis gas compressor 103J. Relevant technical measures were adopted, which made the operating condition improved significantly.
Keywords : synthetic section; 105J; 103J; power consumption
某化肥厂合成氨装置自扩能改造以来,通过技术改造和优化调整,克服生产瓶颈和薄弱环节使合成氨产量达到485kt/a,每t氨的综合能耗达到 35020kJ,实现了装置的达产达标。
1氨气压缩机105-J能力不足 1.1故障现象
装置进入夏季后,循环水温度居高不下,经常
在30℃C以上。氢气压缩机105-J透平调速器PRC 9全开,其控制压力仍超标,105-J氢气吸人量 FRC-9、FRC-10、FRC-11均超过设计值。表明冷
冻系统热负荷太大,105-J能力不足。 1.2原因分析
经过认真的探讨和总结,排除其他原因后,认为冷却器124-C水量不足,影响氨气压缩机105-的做功能力。
冷却器124-C是合成回路中的关键设备。 124-C的水量不足,则124-C出口工艺气温度较高,造成后部氨冷器117-C和118-C的冷冻负荷加大。124-C合成气出口温度设计为35℃,实际达
40℃C,124-C设计温降42℃,热负荷47700kJ/h,差 5%,为设计温差的1/8,约有6000kJ/h的热量没有被水冷却,需105-J做功后的氨来冷却。124-C的气氨液化率大大降低,增加了105-J热负荷,影响
夏季生产负荷。 1.3解决办法
通过分析装置的循环水流量分配.决定对 124-C循环水线进行改造。在装置检修时,从合成氨装置循环水来水总管接来水线进入124-CA/ CB,换热后的水直接进入循环水回水总管上,加大 124-C的循环水量,原124-C循环水线断开,直接进人134-C,回到合成总回水管线。
124-C循环水线改造后,使124-C循环水流通量增大,不仅可以更效地带走124-C合成气热量降低了后部氨冷器117-C,118-C,119-C的热负荷,从而减小冷冻系统负荷,将会大大缓解105-热负荷过高的间题。改造前后工作运行数据见表1。