您当前的位置:首页>论文资料>国内首座1万m3LNG全容储罐的电气设计

国内首座1万m3LNG全容储罐的电气设计

资料类别:论文资料

文档格式:PDF电子版

文件大小:1.87 MB

资料语言:中文

更新时间:2024-12-27 16:16:40



推荐标签:

内容简介

国内首座1万m3LNG全容储罐的电气设计 doi:10.3969/j.issn.16715152.2014.03.006
候影·国内首座1万m'LNG全容储罐的电气设计
国内首座1万m"LNG全容储罐的电气设计
口中国市政工程华北设计研究总院(300074)侯彪

要:针对国内首座1万mLNG全容罐的电气设计,本文对外方设计的内容进行了阐述,并给出了与
我方在相关领域设计的异同;同时对我方配套设计的重点内容进行了论述,意在引起业内专业人士对相关知识点的重视。
关键词:LNG全容储罐LNG潜液泵LNG加压泵断路器
ElectricalDesignoftheDomesticFirstTenThousandCubicMeters
ofLNGFullContainmentTank
North China Municipal Engineering Design and Research InstituteHoubiao
Abstract : In the light of electrical design of the domestic first ten thousand cubic meters of LNG full containment tank.
this paper explicates the design of foreign design, and given our similarities and differences in the relates fields of design; At the same time, the key content of our supporting design are discussed, In order to cause the attention of related industry professionals to such as knowledge point.
Keywords:LNGfull containment tank 1概述
LNG submersiblepump
LNGpressurepump
circuit breaker
2外方设计中的电气部分
国内首座1万m"LNG全容储罐本体由某国外公司设计,该罐砼壁内侧直径28m,拱形罐顶距地面 33m。本体设计所含电气专业部分包括储罐爆炸危险区域划分、防雷保护、接地装置、走道照明和顶部电缆桥架等方面内容。与该罐有关的用电设备包括罐顶LNG潜液泵及罐外LNG加压泵的配电设计由我方配套完成。为便于业内人士对该型储罐电气设计的认识,现就外方及我方配套设计的主要内容简介
如下。万方数据
2.1爆炸危险区域划分
储罐所处爆炸危险环境的危险介质是甲烷、其分级分组为ⅡAT1。危险介质及其分级分组与GB50058-92《爆炸和火灾危险环境电力装置设计规范》附录三气体或蒸气爆炸性混合物分级分组举例完全一致。
危险区域的划分是从全容罐罐壁和罐顶向外沿各方向4.5m以内为爆炸性气体危险环境2区;罐顶设备为从释放源算起沿各方向4.5m以内,以及此球的水平赤道面与罐顶面之间的圆柱体为爆炸性气体危险环
2014/03总第469期129
上一章:电磁式燃气紧急切断阀应用简述 下一章:滇中引水干渠下穿蓝龙潭燃气供应基地的风险分析及建议

相关文章

国内首台20万m3﹢LNG储罐用06Ni9DR钢板的质量控制 全容式LNG储罐的混凝土外罐在预应力荷载作用下的计算分析 Q/SY 1782-2015 高桩承台液化天然气全容储罐蒸发率的测试 LNG全容储罐保冷系统及其性能探究 15万m3大型浮顶储罐规格参数优化设计 SH/T 3564-2017 全容式低温储罐混凝土外罐施工及验收规范 SH/T 3561-2017 液化天然气(LNG)储罐全容式钢制内罐组焊技术规范 国产现场总线控制系统在国内大型百万火电机组的首次成功应用