第4卷第9期 2016年9月
智能电网 Smart Grid
6865806
中图分类号:TM41
Vol. 4 No. 9 Sep.2016
文献标志码:A
基于多源信息的电力变压器全量状态评价模型
郑一鸣,何文林,王文浩,刘浩军,孙翔,詹江杨,邹国平
(国网浙江省电力公司电力科学研究院,浙江省杭州市300014)
PowerTransformerComprehensive ConditionEvaluationModelBased on
Multi-source Information
ZHENG Yiming, HE Wenlin, WANG Wenhao, LIU Haojun, SUN Xiang, ZHAN Jiangyang, ZOU Guoping
(Electric Power Research Institute, State Grid Zhejiang Electric Power Corporation,
Hangzhou 300014, Zhejiang Province, China)
ABSTRACT: In order to adapt to the development trend of the power equipment condition based maintenance and overcome the oeaisse aodoeorde oae e ao oenea oo eoe saaaa e aeaes performance indicators and assessment model, a comprehensive condition evaluation model based on multi-source information is proposed in this paper according to the transformer condition evaluation framework of State Grid Corporation. Combined with the offline test, live detection, on-line monitoring, professional inspection and operating environment, equipment criteria, undesirable service condition and family defects are re-classified in this model. Practice example verifies that the proposed evaluation model can describe the power transformer"s operating state more comprehensively and immediately. The evaluation results can provide scientific guidance for front-line operation and maintenance staff to develop equipment maintenance strategy, and also can provide practical basis for the condition evaluation of other power transformer equipment.
KEY WORDS: power transformer; condition evaluation; undesirable service condition; family defect
摘要:为适应电力设备状态检修的发展趋势,克服传统评价模型在数据获取方式、部件划分、性能指标设置、评分模型等方面的缺陷和不足,依据国家电网公司变压器状态评价框架,结合停电试验、带电检测、在线监测、专业巡检、运行环境等因累,重新梳理了设备状态量、不良工况和家族缺陷等因素,构建了一套综合多源信息的全量状态评价模型。实例分析证明该评价模型更全面、即时地描述了电力变压器的实际运行状态,可为一线运维人员制定设备检修策略提供科学指导,也为其他变电设备的状态评价提供了实践依据。
关键词:电力变压器:状态评价:不良工况:家族缺陷
0引言
在设备运行状态的统计规律的基础上,电网设备检修长期采用定期检修和故障检修相结合的模式。在多年的生产实践中,这种检修模式有效地保障了电网的安全稳定运行。但随着技术进步和电网快速发展,定期检修方式越来越难以适应电网发展的需要,存在“小病大治,无病也治”的首目现象,设备过修与失修现象并存]。电网规模的迅速扩大也导致定期检修工作量剧增,检修人员紧缺、停电安排困难问题日益突出。近年来设备技术水平和制造质量大幅提升,免维护、少维护设备大量投用,早期制定的设备检修、试验规程明显滞后于装备制造水平的发展,因此电网公司全面推广电力设备状
态检修。随着电力设备状态检修技术的推广和成熟,对设备运行情况的准确评估、评价问题也成为电力设备安全稳定运行的重要课题。
电力变压器的状态评价是通过量化反映设备运行状况的直接现象或者由试验手段得到的间接参量,并与导则或规程中的注意值进行对比,最终通过预设的评分模型得出评价结果。目前,美国电力研究院、CSI公司、Netek公司等在状态评价研究中已取得了一些成功"。而我国的电力设备状态评价工作仍处于初级阶段[5-6]。
现行的状态评价导则主要存在如下问题:
1)评价模型主要是基于停电试验获取的参量进行评价。根据实际的运行经验,变压器在运行过