关于刚接柱脚底板厚度计算的讨论
DiscussionaboutComputingthe SoleplateThicknessof RigidColumnBase
刘剑福,王江华
(机械工业第一设计研究院厦门分院,福建厦门361000)
LIU Jian-fu, WANGJiang-hua
(FirstDesign & Research Instituteof Mechanical Industry China ,Xiamen Branch,Xismen361000,China)
建筑与结构设计 a
【摘要】轻钢结构则接柱脚底板厚度现行传统计算方法通常有两种,一种是按柱脚底板下的混凝土基础反力和底板的支承条件计算,另一一种则按照验算铺检受拉一侧底板厚度来计算。按后者计算结果往往远大于按前者,如按此结果应用于实际工程,则可能使得工程造价投入增加,造成不必要的浪费,文章考虑从错检垫板与粒脚底板共同工作推导出柱脚底板厚度计算的修正公式,并总结底板厚度计算的步骤,以期达到应用于实际设计工程的实用性,
[Abstract ]The methods about computing the soleplatethickness ofrigid column baseofsteelstructureoflight-weightbuildinghasalwwystwo atpresent:thefirstoneisaccordingthereactionforceofconcretefoundationand supportconditions ofthesoleplate; the otheroneisdeterminedby the pulling force of the anchor bolt, The latter result is great lager than the former alwsys.It maybe increase the cost of inputs of project and unnecessary waste if we use the result by the traditional methods.This article deduces the corrected formula and the calculation steps by considering the method ofworking together between soleplate ofcolumn base and snchorbolt plaste,inordertoobtain the practicality forprojec byapplingit.
【关键词】柱脚底板;镐检垫板;共同作用
[Keywords Jsoleplateofcolumn base ;anchorboltplate;co-efficient
【中图分类号】TU392.5;TU311.4 1引言
【文献标志码】A
随着我国工业经济的发展,工业厂房设计迎来了新的发展时期,为了追求更快更高的效益,由于钢结构具有建筑简易、施工周期短、自重轻、造价合理等优点,钢结构厂房逐渐成为了新兴的厂房结构形式,得到了广泛的应用。在设计轻型钢结构厂房过程中,笔者发现其钢柱柱脚底板厚度计算时,如按照现行传统计算方法相关公式计算所得底板厚度往往较大
【作者简介】刘剑福(1984~),男,福建安溪人,助理工程师,从事建
筑结设计,(电子信箱)jfo2csfu@yahoo.com.cn 万方数据
【文章编号】1007-9467(2013)04-0047-04
过大的板厚对钢材的性能将提出更高的要求,另一方面也加大了工程的造价投资。由于通常柱脚锚栓处均设置垫板,而垫板发挥的作用往往被忽视,本文就考虑柱脚错栓垫板与底板共同工作加以分析探讨,以期达到应用于实际设计工程的实用性和减少工程造价投人获得更大的效益,通过以下例子来说明错栓垫板与底板共同作用与现行传统柱脚底板厚度计算方法结果的区别。
2现行传统柱脚底板厚度计算方法
关于柱脚底板厚度计算方法,现行《钢结构设计规范) 并无相关直接规定,参照《钢结构设计手册》第三版)风、《钢结构节点连接设计手册》(第二版)等文献主要分为两种方法:
47