玻璃窑余热电站锅炉补给水处理工艺设计
公用工程设计 Alie Chases Dwin
DesignandAnalysisof BoilerMake-upWaterProcess ofPowerPlantwithExhaustHeatin
GlassFurnace 史大鸣,李春林
(中国中元国际工程公司,北京100089)
SHI Da-ming,LI Chun-lin
(China IPPRIntermational Engineering Corp-,Beijing 100089,China)
【摘要】余热发电通常规模小,锅炉补给水处理工艺系统和处理设各、规模有其自身特点,通过分析低参数余热发电锅炉的水质要求,结合现代锅炉补给水处理技术的发展,分析并选择适合玻瑞客低参数余热发电项目要求的锅炉补给水处理方式。
[Abstract]Asmallercapacityofpowergeneration withexhaustheat inglassfumace,theboilermakeup waterprocesshasthesignificant processing umit and performance.According to the modem water treatment technologies,the technical comparison and analysis,on the water oe degree of automation and convenient operation, no production of acid and alkali wastewster, It is by fur the optimum selection for the boiler
make-up watertreatment system withexhaustbeatinglassfurnace.【关键词】余热电站;补龄水;反渗进;软化
[Key words )powerplant with exhaust heat; make-up water;reverse osmosis; soften
【中图分类号】TU991.2;TU271.1 1前言
【文献标志码】A
玻璃行业是一个高能耗行业,玻璃熔窑是玻璃生产线能耗最多的设备,在玻璃成本中燃料成本约占35%~50%,我国玻璃熔窑的热效率平均只有25%~35%,玻璃窑排出的废烟
【作者简介】史大鸣(1956~】,男,河南西平人,高级工程师,从事给
排水工程设计与研究,电子信箱)shidamingeippr.net。万方数据
【文章编号】1007-9467(2013)12-0097-03
气温度在490~590℃之间,浪费了很多热量。为节约能源,目前玻璃生产企业利用烟气的热量进行发电。某玻璃生产厂有3 条600t/d的玻璃窑生产线,经计算可配置3台余热锅炉,每台余热钢炉的额定蒸汽压力为2.53MPa,过热蒸汽温度450℃,设计蒸汽产量15/h,发电机总安装容量为9MW。该余热钢炉的过热蒸汽压力比常规的电站钢炉要低得多,温度与电站锅炉的中压锅炉一致,整个电站的规模也很小,属于自备电站性质。钢炉补给水处理系统的设计既要满足锅炉要求,又要考虑
97