您当前的位置:首页>论文资料>超高层建筑给排水设计与探讨

超高层建筑给排水设计与探讨

资料类别:论文资料

文档格式:PDF电子版

文件大小:290.67 KB

资料语言:中文

更新时间:2024-12-27 11:53:57



推荐标签:

内容简介

超高层建筑给排水设计与探讨 工程建设与设计
iAn
超高层建筑给排水设计与探讨
Studyon Waterand Drain Design of Super High-rise Building
符翠红
(惠州诚艺建筑设计有限公司,广东惠州516000)
FU Cui-hong
(Huizhou Construction Design.LtdofChengyi, Huizhou516000,China)
【摘要】随着建筑设计方策的复杂化,尤其是对于超高层建筑,其给持水的设计更应该合理灵活地布置,作者紧密结合某超高层建筑始排水工程的设计与施工实残,对超高层建筑中给水系统、热水系统以及给水管的管材选取和管道数设等间题进行了探计,
[Abstract]As the building design complicated, especially for super high-rise buildings, the water and drain design should arrange more flexible and reasonable, and construct more need to ensure the quality. By closely integrated design and construction practioce ofsuperhigh-rise building, the shrunk system,hot water pipe and select the pipe were dicussed, these can
providereferences forthe waterand drain design and constructionofsuperhigh-rise buildings.【关键词】高层建筑;给排水设计;给水系统;输神水施工
[Keywords Jhigh-rise building; waterand drain design; shrunk system; water anddrain construction
【中图分类号】TU821;TU823 1项目简介
【文献标志码]A
卓越-皇岗世纪中心是卓越地产与皇岗实业有限公司共同开发的深圳市目前为止最大的、最著名的城市综合体之一。为超高层建筑。东西宽200m,南北长165m,地形西北角相对较高,内部地势平坦。规划要求于用地中间设置不小于4000m的集中广场,并于广场周边设置进深大于 3.5m,层高不大于5.5m的骑楼,四栋塔楼于四个角部设置。本项目设地下3层,地上裙楼5层,主楼由四栋超高层建筑组成,分居基地四个角,由裙楼及塔楼围合的中心为一集中广场。本工程两路由DN200mm给水管接人室外给水管网,并于室外成环状布置。生活给水系统分为直接供
【作者简介】符翠红(1978-),女,江西宁部人,工程师,从事建筑工程专业
实验数学与研究,(电子信霜)bodolw@126.coma 96
万方数据
【文章编号】1007-9467(2011)04-0096-04
水系统和水泵加压供水系统。根据甲方提供的市政条件,市政给水水压为0.40MPa,此系统直接供水至地下3层生活水池及消防水池、裙房商业1层~4层的各用水点。绿化谨溉、冲洗道路及停车库用水采用空调冷凝水回用,当空调冷凝水不足时,利用市政压力供水补充。笔者针对其中的2号楼(总建筑高度为256m)建筑给排水专业的设计进行探讨与总结。
2给排水设计 2.1给水系统设计
1)给水系统竖向分区。对于超高层的建筑物,当室外给水管网水压不能满足室内用水且一次加压无法满足高层用水时,应将其竖向分区,各分区可采用不同的给水方式,本工程给水系统竖向分区如下:I区为地下3层~地上4 层,由市政压力直接供给;Ⅱ区为5层~10层,由设于14