hanghai Energy Conservation 上海节能
节能工程
电站定速锅炉给水泵节能降耗的简捷途径
上海上电电力工程有限公司
章健
摘要:节能减排已是全社会共同而紧迫的任务,一些中小型供热电站,因建设投资及运营成本问题,选用电动定速锅炉给水泵,随着节能减排工作深入和电站效益下降的压力增大,在资金相对紧张的条件下,上海某热电站对定速泵分阶段进行节能等综合改造,取得了较好效果。
关键调:定速锅炉给水泵,节能,优化汽水品质
Simply Energy-Saving and Consumption-Reducing Methods of Fixed
SpeedBoilerFeedWaterPumpsinPowerPlant
Zhang jian
Abstract: Energysaving and consumption -reducing is an joint and urgent task for the whole society. Some small and medium sized heating power plant chose fixed speed boiler feed water pumps due to construction investment and operation cost.With the depth of eeaeeee in the condition of relatively tight capital, some shanghai power plant made energy-saving renovation for fixed speed boiler feed water pumps step by step and achieved better results
Keywords:fixed speed boiler feed water pumps,energy-saving and emission-reducing, optimizationofsteam-waterquality
1设备概况
该热电厂共装有2台燃煤汽包炉,共配置3
台FT270-140(5)型电动给水泵,技术参数见表(1),给水泵结构图见图1,母管制给水系统,两用一备,给水系统见图2。主蒸汽通过减温减压站向化工区供汽,另作为某燃煤电站2× 1000MW机组应急备
40
用辅助汽源,投产后存在着电耗高及汽水品质差等问题。
表1FT270-140(5)型电动给水泵技术参数
锅炉技术参数
额定蒸发量(t/h)排放压力(MPa)汽包压力(MPa)
汽包安全阔起座压力(MPa)汽包安全阀排放能力(t/h)过热器工作压力(MPa)过热器安全阀起座压力(MPa)过热器安全阀排放能力(t/h)
ANGHAIENERGY CONSERVATIO 2012年第71
万方数据
130短时最大蒸发量150) 8.2 (820m)
6.27 6.65 127.039 5.7 5.93 39.508
给水泵技术参数
排放流量(t/h)泵效率(%) 泵轴功率(kW) 泵转速(r/min)除氧器水面标高(m)介质温度(℃)
220 80 615 2980 15
100(=0.955)