第29卷第6期 2017年12月
浙江水利水电学院学报
J Zhejiang Univ of Wat. Res & Electric Pow.
DOI: 10.3969/j. issn2095 -7092.2017.06.012
计量终端备用电池控制方法及应用
昊飞财
(福建水利电力职业技术学院,福建永安366000)
Vol.29No.6 Dec2017
摘要:计量终端的备用电池在长期使用中容易出现容量衰减快无法提供大电流等问题.基于此提出了一种适用于备用电池模块的控制方法,具有电池充放电、容量检测以及电池激活等功能,解决电池过充过放、容量大幅下降、保护等间题介绍了备用电池模块的各种运行模式工作机制,放电实验和充电实验证明,通过IED负载和超级
电容的有机组合,可实现电池模块在线激活维护,提高终端备用电源的可靠性关键词:计量终端;备用电池;电池管理
中图分类号TM932
文献标志码:A
文章编号:1008536X(2017)06-0055-05
AppicationofBackupBatteryControlforEectricEnergyTerminals
WU Fei-cai
( Fujian College of Water Conservancy and Electric Power , Yongan 366000 , China )
Abstract ; The backup batteries in electric energy terminals tend to reduce capacity and be unable to produce sufficient cur -rent in long term use. This paper proposes a novel management method suitable for backup battery , which is able to charge, discharge, activate battery and test the capacity - These functions are useful to protect battery and prolong its life -The operation models and working mechanism are deseribed in details . Two experiments have been conducted to show the
performance of the method which could improve the reliability of backup battery -K y words ;electric energy teminal ; backup battery ; battery management
智能计量终端在电网公司用电信息采集系统中起着“承上启下”的作用终端对下采集汇聚电能表数据,对上将处理后的电能量数据传送至主站是重要的信息采集设备1-3.在外部停电状态下,终端需具备电能表停电信息收集与上报、电能量数据采集与分析、故障记录与交互等功能因此需要电池组提供可靠的备用电源供应目前电网公司使用的备用电池主要为镍氢电池,存在着可靠性低容量衰减快、监测方法弱等缺点.现有关于电池管理系统的研究文献大多关注汽车的电池管理或者新能源发电的电池控制方法,而适用于计量终端备用电池的控制和保护方法比较少见[4-7].本文首先分析影响备用电池使用寿命与可靠性供电的主要
收稿日期:2017-06-24
作者简介:吴飞财(979-),男,福建永安人,硕士,讲师,研究方向为电能计量、电气自动化、
万方数据
因素,然后提出一种新的备用电池控制方法,最后通过实验数据进行对比分析,
问题分析
(1)电池容量测试
选择10组已使用6~12m的电池先将电池电压充电至5.8V再利用安时积分法以60mA的放电电流测试每组电池的容量*,结果(见图1)
根据技术规范的要求,备用电池的额定容量需 ≥600mAh,而上述10组电池的容量仅为额定容量的1%~26%,明显低于额定容量的要求[2-3]
(2)大电流放电测试
将待测的10组电池充电至5.8V,再通过阻性负载以600mA的电流放电,记录电池电压降到 4.2V时的持续时间,测试结果(见图2.