第39卷第2期 2010年6月
热力透平 THERMAL TURBINE
Vol. 39 No. 2 Jun.2010
高压加热器解列对机组安全及经济性的影响
邢希东
(天津大唐国际盘山发电有限黄任公司,天津萄县301900)
摘要:结合某电厂一起高加异常解列事故,详细分析了事故对机组安全性和经济性的具体影响。重点从高加本体、机组负荷、锅炉侧和汽机侧等4个方面对机组安全性的影响进行了分析。总结出掌握好事故处理过
程中的调整提前量,可以将事政影响控制在可控的最小范国内,以提高机组运行的安全性和经济性。关键调:高压加热器;水位保护:受热面超温:汽轮机进水
中图分类号:TK267
文献标识码:A
文章编号:1672—5549(2010)020144—03
InfluenceofHigh-PressureHeatersStep-outon
Unit' Security and Economy
XING Xi-dong
(Tianjin Datang International Panshan Power Generation Co. ,Ltd. , Jixian Tianjin 301900, China)
Abstract:The influence of the step-out incident in a power plant on unit' security and economy is analyzed, and the main aspects such as high-pressure proper, unit load, boiler and steam turbine side are investigated. Thus the incident can be controlled under the minimum degree by adjusting during the incident dealing, which can improve security and economy in power plant.
Key words:high-pressure heater; water level protection;over-temperature heating surface: turbine water inlet
高压加热器事故解列后对机组产生的不良影响做
1
高压加热器系统简介
1.1
高压加热器及系统介绍
该电厂高加系统采用的是“大旁路”系统,配置了高加组入口旁路联合阀(ac导通则表示高加投人运行,ab导通则为高加旁路投入运行)。高加正常疏水采用了“1号→+2号-→3号→除氧器” 的逐级自流方式,每台高加都有事故疏水阀放水至凝汽器疏水扩容器。其水侧汽侧的系统布置如下图所示(图1)。
1.2高压加热器的保护
一般高加的保护设备有给水旁路装置、防抽汽倒流装置、水侧汽侧防爆安全门、事故疏水装置等。同时配有高水位保护逻辑,用来实现水位高报警和触发水位保护动作。该电厂600MW机组高加水位保护设置情况如下表1所示。
高压加热器的运行维护十分复杂。本文仅对收稿日期:2009—05-26
一简单分析。
表1 名称
高服水位高Ⅱ水位高I水位正常水位低1水位
2
某国产600MW机组高加水位保护设置情况
数值(mm) +138 +88 +38 0 38
动作结果
高加解列,抽气逆止门电动门关闭。
水侧走旁路
事故疏水阀全开,上级正常疏水门关闭
光字"高加水位高"报警
正常运行
光字“高加水位低"报警
高加事故解列案例过程介绍
事故发生前机组负荷580MW,AGC(负荷自
动控制)正常投人,机组协调投入,运行正常。
1034监盘人员发现#2高加水位突变为 770mm,水位H,HH,HHH报警,同时光字牌发“高加水位高”报警,正常疏水、事故疏水调整门全
作者简介:邢希东(1976一),男,毕业于华北电力大学,大学学历,工程师,现从事火电厂集控运行技术和管理、节能管理、绩效管理等工
作。
144