2013年第6期(总第186期)
doi;10.3969/j. issn. 1009 3230.2013.06.006
应用能源技术
SCR装置流场数值模拟与冷模试验对比分析
姜述杰,薛子畅
(哈尔滨工业大学,哈尔滨150006)
摘要:文中以某燃煤机组SCR脱硝反应系统的优化流场分析为例,利用数值模拟和冷模试验两种方法对SCR系统流场进行研究,并将数值模拟与冷模试验的结果进行对比分析,验证数值模拟的准确性,为SCR系统结构设计及优化提供重要参考依据。
关键词:烟气脱硝;选择性催化还原;流场;数值模拟;冷模试验
2文献标志码:B文章编号:1009-3230(2013)06-0017-03
中图分类号:TK223.2
ComparativeAnalysisofFlowFieldNumericalSimulation
andColdModelTestofSCRSystem
JIANG Shu jie', XUE Zi chang"
(HarbinInstituteofTechnology,Harbin150006,China)
Abstract: This paper describes optimization of SCR flow field based on one flue gas denitrification project in coal fired power plant.The optimization of flow field is perfomed by comparison with
17
Numerical simulation and Cold Model Test. According to the comparison results, the accuracy of numerical simulation is verified. Consequently the results of numerical simulation can provide important parameters for the design and improvement of SCR system.
Key words: Flue gas denitrification; Selective Catalytic Reduction (SCR); Flue field; Numerical simulation; Cold Model Test
0引言
NO,是大气主要污染物之一,其中煤燃烧排放的NOx约占NOx排放总量的70%以上。我国是以燃煤为主的发展中国家,随着经济的快速发展,燃煤需求量不断增大,因此NOx的污染已成为个不容忽视的问题。
针对燃煤烟气NOx的治理,迄今已开发出多种NOx控制技术(1)。在NO,处理的若干技术中,选择性催化还原技术(SCR)以其高NO,脱除率、收稿日期:201304-11修订日期:2013-0425 作者菌介:姜述杰(1975-),女,高级工程师,1998年毕业
于佳木斯大学工学院热能工程专业,现就读于哈尔滨工业大学能源学院,曾从事火电厂锅炉及辑机设计工作。
万方数据
技术成熟可靠、经济实用性好等优点成为大型燃煤电站烟气脱硝技术的主要选择[2-3]。在SCR 技术实施过程中,为了最大限度满足设计要求,保证系统能够达到应有的设计指标,往往需要采用数值模拟方法对整个系统的流场进行计算分析,以保证进入反应器前的NO,和氨气达到良好的瑞流混合,确保速度分布、烟气分布以及还原剂浓度分布最佳,系统压力损失最小[4]。除此之外,为了检验数值模拟的可靠性,并对流场进行深入的研究,还需要建立实物模型进行试验测试。
文中以某燃煤机组SCR脱硝反应系统的优化流场分析为例,将数值模拟与冷模试验的模拟结果进行了对比分析,验证了数值模拟的准确性。