46
doi:10. 3969/j. issn. 1009 3230.2013.04. 012
应用能源技术
2013年第4期(总第184期)
天型光伏电站电气汇集系统设计的讨论
冯卫青',严峰峰”
00000)
摘要:通过对大型并网光伏电站直流汇集系统设计的介绍,结合光伏电站设计实例,从工程实际应用角度对光伏电站直流汇集系统设计方案提出优化建议,从而提高光伏电站的发电效率,及降低光伙电站的工程投资。
关键调:光伏电站;直流汇集系统;设计
中图分类号:TK512
文献标志码:B
文章编号:10093230(2013)04004604
Discussion about theLarge PVPower Station Electrical
CollectionSystemDesion FENG Wei-qing', YAN Feng-feng
(1.State Nuclear Electric Power Planning Design & Research Institute, Beijing 100095, China;
2.Beijing Juhe Electrical Engineering Design Limited,Beijing 100048, China)
Abstract: Through the introduction of large grid connected PV power station DC collection system design, combined with the PV power plant design examples, from the practical application of engineering point of view on the PV power station the DC collection system design optimization suggestions, to further improve the power generation efficiency of PV power plants, further reduce PV power plant project investment.
Key words: PV power station; DC collection system; Design
0引言
随着国家对太阳能光伏产业的大力扶持,近年来,国内大型并网光伏电站的建设得到了快速发展。通过对大型并网光伏电站常用的直流汇集系统设计的介绍,结合光伏电站设计实例,从工程实际应用角度对光伏电站直流汇集系统设计方案提出优化建议,以进一步提高光伏电站的发电效率,进一步降低光伏电站的工程投资【1]。
1大型并网光伏电站典型直流汇集系统电气接线
大型并网型光伏电站典型直流汇集系统接线如下:光伏组件经过串并联后形成光伏子串,光伏
收稿日期:20130308
修订日期:20130319
作者简介:冯卫青(1980-),女,主要从事电力系统自动化
研究。
万方数据
子串接人光伏阵列直流防雷汇流箱进行一次汇流,一次汇流完成的若平个子单元组成光伏阵列后再经过直流配电柜进行二次汇流接人光伏并网逆变器,经逆变器逆变后通过0.27(0.315)/ 10kV(35kV)(逆变器交流输出有270V、315V 等)就地升压变压器升压,若干个发电单元的就地升压变经电缆并接为1回集电线路后接入升压站内的35kV或10kV)配电装置进行电能量汇集、升压,而后并入电网2)。
光伏电站直流系统接线可分为如下三部分,第一部分为光伏组件审联系统的接线;第二部分为串联后的光伏子串并接入汇流箱的接线;第三部分为汇流箱并接人直流配电柜的接线(3)。