26
doi :10. 3969/j. issn. 1009 3230.2013.01. 006
应用能源技术
2013年第1期(总第181期)
浅谈300MW供热机组凝结水泵的优化配置
李建,丁伟霞
(开深东方发电二期工程项目筹建处,河北唐山063103)
摘要:疑结水录是火力发电厂主要动力设备之一,该系统配置是否合理,不仅直接影响机组整体运行的经济性,而且对机组整体安全性电有重大影响。文中采用最小年费用法,从技术可靠性、运行经济性两方面对目前常用的凝结水泵变频配置方案进行比较,进而得出300MW亚临界供热机组凝泵的最优配置方案。
关键词:300MW;供热机;凝结水泵;最小年费用
中图分类号:TK284.7
文献标志码:B
文章编号:1009-3230(2013)01-0026-03
Discussionon3ooMWHeatingUnitCondensatePumpto
OptimizeConfiguration LI Jian-kun, DING Wei-xia
(Kailuan Oriental Power PhaseTwo Project Preparatory Office,Tangshan 063103,China) Abstract:The condensate pump is one of the main thermal power equipment,the system configuration is reasonable, not only directly affcct the overall operation of the unit economy,and on the unit overall safety also have important influence. Article based on the minimum annual cost method,from the technical reliability, running two aspects of economy at present commonly used condensate pump variable frequency configuration scheme comparison, and then conclusion that the
300MW subcritical heating unit condensate pump optimal allocation scheme. Key words:30oMW;Heating unit;Condensate pump;Minimum annual cost
0
引言
文中工程拟建2台300MW国产亚临界、一
次中间再热、供热机组。凝结水流量季节性变化很大,要求凝泵系统必须有更高的运行灵活性和适应性。而高压变频技术通过调节系的转速,不仅使泵可以较好地适应流量变化,而且还能明显地提高泵在非设计流量时的运行效率,因此应将变频技术应用到本工程,并与凝结泵进行优化配置(1-3)
300MW级供热机组凝泵常用变频配置方案
目前国内300MW级供热机组中,常见的凝
收稿日期:2012-1018
修订日期:2012-12-15
作者简介:李建望(1967-),中国矿业大学(北京)在读硕
士,长期从事热能动力专业研究,现任开滦东方发电二期工程项目筹建处主任。
万方数据
泵变频调速配置方案详见下表1。
表1 方案综号方案— 方案二方案三方案四
凝泵变频调速配置方案
凝泵数量
聚系流量
冶台 2 2 3 3
/% 110 110 55 55
电机数量冶 2 2 3 3
2
:各方案技术比较 2.1方案一技术特点
变频器数量/台-0 0 2
每台供热机组设2台110%流量的凝泵,配1 套变频器。变额器与疑泵的电机设计为一拖二的