第34卷第4期 2014年12月
核科学与工程
Nuclear Science and Engineering
Vol.34No.4
Dec.2014
压水堆一回路冷却剂环境中痕量锌的测定研究
米争峰,黄文杰,徐迟(中国原子能科举研究院,北京102413)
摘要:建立用石墨炉原子吸收法测定压水堆一回路冷却剂环境中痕量锌的方法。研究了仪器的工作条件、空自的选择、锌溶滤稳定性及硼酸、氢复化锂的影响。本方法的回收率在96.7%~105.0%之间 2.0μg/L锌的相对标准偏差为3.7%,检出限为0.12μg/L。用本方法为某压水堆实验回路中进行了锌的测定,取得了满意的结果。
关键调:一回路冷却剂;锌;石墨炉原子吸收
中图分类号:TL42
文章标志码:A
文章编号:0258-0918(2014)04-0433-04
Study onDetermination of TraceZinc in Primary Circuit of PWR
MI Zheng-feng, HUANG Wen-jie, XU Chi(China Institute of Atomice Energy, Beijing 102413, China)
Abstract: Amethod has been developed to determine trace zinc in primary circuit of pressurized-water reactor by Graphite furnace atomic absorption spectrometry.The working conditions of the instrument, the choice of blank solution, the effects of boric acid and lithium hydroxide, and the stability about zinc has been studied in this paper. The recovery percentage is 96.7%~105.0%.The relative standard deviation for 2μg/L Zn is 3.7%, and the detection limit is 0.12μg/L. The method has been applied t determine zinc in the experimental primary circuit of PWR, and the results are satisfied. Keywords:primary circuit; zinc; Graphite furnace atomic absorption
目前,在美国和欧洲一些国家的压水堆核电站,菩遍在一回路冷却剂中注入约5~ 30μg/L的锌溶液,我国正在建设的AP1000 系列核电机组运行时也将采用注锌水化学工艺(2),其可降低一回路水应力腐蚀作用,减少堆芯材料向一回路冷却剂中释放所导致的辐射水平增加。无论是压水堆注锌工艺研究还是将
收稿日期:2014-09-16;修回日期:2014-11-17
来的具体应用,均要求对冷却剂中的锌准确测定。目前一回路冷却剂中锌的测定方法国内还尚未见报道。对于水中锌的测定,火焰原子吸收法(FAA)或石墨炉原子吸收法(GFAA)都是比较理想的分析方法,FAA必须经数十倍预富集后方测定痕量锌,由于各种试剂和周围环境都普遍存在着锌,预富集过程中难免不受到
作者简介:米争峰(1986一),男,山西人,研究实习员,硕士,现从事中国实验快堆销分析工作
433