第32卷增刊2 2012年
12月
核科学与工程
Nuclear Science and Engineering
Vol.32
Suppl.2
Dec.
CPR1000严重事故仪表鉴定要求的
对比分析及应用唐华雄,严加洪,汪伟,张宏亮(深圳中产核工程设计有限公司,广东深圳518045)
2012
摘要:本文以设计基准事故工况下的设备鉴定要求为基础,对中、美、法设备鉴定标准进行对比分析,提出用于CPR1000产重事故预防和缓解的仪表鉴定要求,以用于指导CPR1000严重事故仪表的研发以及工程选型。
关键词;严重事故,仅表鉴定;CPR1000
中图分类号:TM623
文章标志码:B
文章端号:0258-0918(2012)S2-0179-05
AnalysisandApplicationfortheCPR1000Severe
AccidentInstrumentationQualification
TANG Hua-xiong,YAN Jia-hong,WANG Wei,ZHANG Hong-liang(China Nuelear Power Design Co. , Ltd. (Shenzhen), Shenzhen, Guangdong Prov. 518045, China)
Abstract; The paper comparatively analyzes the qualification standards of China, America and France based on the equipment qualification requirements under design-basis accident condition and proposes the instrumentation qualification requirements which are applied to the prevention and mitigation of CRP1000 severe accidents. The paper is aimed to give instructions to the R&.D and engineering of CPR10oo severe accident instrumentation.
Key words: severe accident; instrumentation qualification;CPR1oo0
福岛核事故的直接原因归咎于海啸引起的长时间全厂断电,燃料余热无法及时排除造成堆芯迅速升温,高温/高压造成密封功能降低,氢气通过安全壳贯穿部位泄漏,引发反应堆厂房爆炸,造成放射性物质释放。福岛核事故再一次证明了在严重事故环境下,保证事故处理
收日期:2012-09-22,修图日期:2012-10-22
及应急所需设备可用性的重要性。仪控设备肩负着核电厂安全稳定运行和保护公众安全的重大责任,因此有必要对产重事敬处理和应急所需的仪表进行严重事故环境条件下的设备鉴定,这对缓解事故的后果,提高核电厂的安全水平非常重要。CPR1000仪表鉴定标准仪考虑
作者简介:唐华综(1983),男,期北人,工程师,予士,现主要从事核岛仪控设计工作
179