2018年第3期(总第243期)
doi:10. 3969/j. issn. 1009 3230.2018.03.005
应用能源技术
某供热机组锅炉给水泵液偶改变频
调速汽蚀安全性分析
吕玉坤,李超
(华北电力大学,河北保定071003)
摘要:文中对某2×300MW及2×330MW供热机组锅炉给水泵液力偶合器改变频器调速方案进行了现场调研,计算了变频改造后各种工况下除氧器至给水泵入口段的管路损失,并结合前置泵的运行数据对给水泵入口有效汽蚀余量和必须汽蚀余量进行了校核计算。结果表明:变频改造后,其前置泵转速在1000~1490r/min范围内变化时,给水泵组入口有效汽蚀余量均大于其必需汽蚀余量。该改造方案能够满足给水泵组汽蚀安全性要求。
关键调:给水泵;变频改造;汽蚀;安全性
中图分类号:TK229.4文献标志码:B
文章编号:10093230(2018)03-0017-04
17
RequencyTransformationof CentrifugalPumpPerformanceTestSystem
LV Yu kun, LI Chao
(North China Electric Power University, Baoding 071003,Hebei Province, China)
Abstract: Site investigation, for the taiyuan second thermal power plant is calculated after the inverter deaerator under various working conditions to the pump inlet section of the line loss, and according to the operation data of feed water pump booster pump inlet effective NPSH and must NPSH, this article offer reference for engineering design review. Results show that the feed water pump unit group after frequency conversion innovation of hydraulic coupler speed regulation, the booster pump rotation speed, within the range of 1000 ~ 1490 r/min to pump group entry valid
NPSH were greater than the required NPSH, can satisfy the cavitation security requirement. Key words: Pump; Frequency conversion; Cavitation; Security
0引言
给水泵是电厂的重要辅机之一,其运行可靠性直接影响到电厂的安全运行。在给水泵选型和布置时,应对其必需汽蚀余量和有效汽蚀余量进行校计算,以确保给水泵组在现场规定的运行工况范围内能够安全运行而不发生汽蚀现象。
某2×300MW热电厂2×330MW机组配备有6台液力耦合器调速电动锅炉给水泵,给水泵是上海电力修造厂生产的DC600型锅炉给水泵,
收稿日期:20171225
修订日期:20180125
作者简介:昌玉坤,华北电力大学。万方数据
液力偶合器是德国福依特公司生产的YOT51A型液力偶合器,给水泵电动机是上海电机厂生产的 YKS5400-4三相异步电机。
改造前,前置泵以1490r/min定速运行,改造后其最低转速为1000t/min。由于前置泵转速下降,其出口压力降低,致使给水泵入口有效汽蚀余量降低,有可能危及给水泵组的安全运行。因此,必需对给水泵入口汽蚀特性进行校核计算。
除氧器至前置泵的管路损失 1
这个厂机组配有三台50%负荷的电动给水泵A、B、C,运行方式为两运一备。据此,以泵C 为例,首先计算除氧器至前置人口段管路损失。