2010年第10期(总第154期)
应用能源技术
关于锅炉汽包上下壁温差40℃限制值的
理论推导和寿命损耗计算
王慧文
(哈尔滨锅炉厂有限责任公司,黑龙江哈尔滨150046)
摘要:介绍了经典力学理论对锅炉汽包上下壁温差限制值40℃推导的历史过程,并用最新(2008年额布)的国标定量计算了目前国内主力发电锅炉机组汽包上下壁温差在整个汽包疲劳寿命中所占的份量。
关键词:锅炉汽包;上下壁;温差;寿命损耗
3文章编号:1009~3230(2010)10=0025-03
中图分类号:TK229.2
文献标志码:B
TheTheoreticalDeductionandtheLifeExpenditureCalculation
fortheProvisiononTemperatureDifference4o℃
Between upanddownWall of Boiler Drum
WANGHui-wen
(Harbin Boiler Co.,Ltd.Harbin 150046,China
Abstract: This paper introduced the historical process for the provision of the temperature difference 40 between up and down wall of the boiler drum,using classical mechanics theory , and quantitavily calculated the sharing partion in intire life expenditure for the temperature diffence 40°C on present main power boiler unites with help of the newest national standard (2008 publication) Key words: Boiler drum; Up and down wall; Temperature difference; Life expenditure
0前言
目前我国各电厂运行手册中都明确规定锅炉运行过程中汽包上下壁温差不能超过40℃。将运行信号警告值明确限定在40℃,一且超过则报警。于是在锅炉调试过程中甚至出现频频报警的现象。哈尔滨锅炉厂有限责任公司安装代表与电厂方面曾多次来电查询这个确定40℃温差的原因,以及一旦报警会产生什么样的危害?我们对这方面的理解与探索说明如下。
1前苏联用经典力学理论对锅炉汽
包上下壁温差限制值的推导
这40℃温差的限制值是多年以前从原苏联引进的。上世纪40~50年代,原苏联的电力收稿日期:2010-16-15
修订日期:2010=09-21
作者简介:王慧文(1978-),女,黑龙江哈尔滨人,工程师,
主要从事锅炉管道应力分析与强度设计工作。
万方数据
25
工业达到世界先进水平,十万千万(100MW)的锅炉批量生产。锅炉的启动和停炉时汽包强度间题得到深入研究,锅炉的汽包上下壁温差一直是锅炉工程师最关心的问题之一,1957年前苏联学者用经典力学公式推导出汽包在整个运行过程的限制值。
推导过程与原理基本是:在汽包运行过程中产生最大应力的区域是下半部底部内壁处。假定汽包下半部某处应力分量分别为环向应力分量 O。,径向应力分量,,轴向应力分量按传统的厚壁简体力学分析,在纯内压P的作用下
k2 +1,."-1 Dn
式中,k-
为汽包外径与内径的比值。 D
(1)