2014年11月下第43卷第22期
DOI:10. 7672/sgjs2014220087
施工技术
CONSTRUCTION TECHNOLOGY
某混凝土框架结构厂房加固与改造
徐国明
(天脊煤化工集团股份有限公司,山西游城047507)
[摘要]为了对一栋3层钢筋混凝土框架结构的旧厂房进行改造,查阅了原厂房的地质、设计及施工资料,进行了现场调查,并对其混凝土强度等级和地基土允许承载力特征值进行了现场鉴定。根据现行规范要求,对其地基、基
础、一层框架柱、楼盖的部分梁及板进行了加固,更换了屋盖,满足了使用要求。【关键词]混凝土;框架结构;厂房;改造;加固
[中图分类号]TU746.3
【文献标识码]A
[文章编号】1002-8498(2014)22-0087-04
Reinforcement and Retrofitting on a Reinforced Concrete
FrameStructureWorkshop
Xu Guoming
( Tianji Coal Chemical Industry Group Co. ,Lid. ,Lacheng, Shanxi 047507, China)
Abstract:For retrofitting a three-storey reinforced concreteframe structure,the author finds the geological report, design and construction records of the existing workshop, does the on-site survey. And the concrete strength grade and the allowable bearing capacity of foundation are on-site appraised. Based on the code requirement,the ground and foundation,one-storey frame columns,part of beams and slabs are reinforced, and the roof is replaced which satisfy the use ability
Key words:concrete;framed structure;workshop;retrofitting;reinforcements
1工程概况
大脊集团厂区有一栋3层混凝土框架结构的石灰乳制备厂房,自1987年初开始投入运行,到2011 年12月停止使用,历经25年的生产运行,一切正常。由于扩大生产规模、增加环保配套设施,需要将原厂房内的石灰乳生产设备全部拆除,在其1,2 层布置第2套废水深度处理回用装置,把3层改造成办公区。由于用途的彻底改变、简载的大量增加,致使改造加固的工程量很大。为满足使用要求,保证结构安全,更换了屋盖,加固了承载力不足的柱、梁和板,并将原柱之下独立基础改造成条形基础,还对地基进行了打桩加固。
2原建筑物概况 2.1地质条件
根据工程地质勘察报告:该工程位于“合成Ⅱ 区一B86号探井、B87钻孔”附近,地基土属Ⅲ级自重湿陷性黄土。从上向下:①Q4al+F黄土状亚黏土,
【作者简介】徐国明,国家二级注册建筑师,国家二级注册结构工程
师,注册监理工程师,E-mail;xgm-sxle@163.com[收稿日期]2014-03-09
87
高压缩性,层厚6.50~4.65m,有湿陷性;②Qa+黄土状亚黏土,中压缩性,层厚1.75~1.15m,有湿陷性;③Q2"+"黄土状亚黏土,中低压缩性,无湿陷性,
层厚>11.75m。 2.2地基处理
地基处理采用3000kN·m能量的强夯能级进行施工。1984年6月对强夯后的地基进行测试:消除湿陷性深度7m,土的干容重Ya>1.5g/cm,影响深度为5m,压缩模量E。=11.05~11.81MPa,地基承载力特征值[R]=235.8~289.5kPa。强夯后的地基允许承载力特征值取230kPa。室内地坪土 0.000相当于绝对标高931.55m,强务后的实际整
平标高为927.88m,即-3.67m。 2.3建筑物现状
经专业人员对已使用25年的3层框架结构进行现场勘验,发现1层有1个大门门垛被撞坏,屋盖上许多预制大型屋面板损坏,有的底面钢筋腐蚀,还有的钢筋外露。原现浇的钢筋混凝土板、梁、柱及黏土砖墙完好无损。