12
D01:10.7672/sgjs2013160012
施工技术
CONSTRUCTION TECHNOLOGY
2013年8月下第42卷第16期
内嵌混凝土构造柱-圈梁抗震加固砌体
结构试验研究* 郑昊,朱春明,吉峰,姜浩
(上海市建筑科学研究院上海市工程结构新技术重点实验室,上海200032)
【摘要】对两层两开间1:2翻体结构空间模型采用后加内嵌混凝土构造柱-圈梁加固后,进行低周反复荷载作用下的试验研究,同时与已有构造柱-圈梁的翻体结构空间模型进行对比。结果表明,砌体结构采用内嵌混凝土构造柱
圈梁加固其有良好的抗震承载能力和延性,与原有构造柱-图的砌体结构相比,抗震承载力及延性相近。【关键词】抗震;加固;砌体结构荷载试验
【中图分类号】TU362
【文献标识码】A
【文章编号】1002-8498(2013)16-0012-04
StudyonSeismicPerformanceofMasonryStructureStrengthened withEmbeddedConcreteConstructionalColumnandRingBeam
Zheng Hao,Zhu Chunming,Ji Feng,Jiang Hao
( Shanghai Key Laboratory of New Technology for Engineering Structures, SRIBS, Shanghai 200032, China)
Abstract: Strengthened with embedded concrete constructional column and ring beam, the double-story and double-bay masonry structure is studied by testing of low reversed cyclic loading, meanwhile, it is compared with the same model with concrete constructional column and ring beam. Test results show that it has better seismic performance and ductility and gets close to masonry structure with concrete constructional column and ring beam.
Key words: seismic ;strengthening; masonry structure; load testing
1概述
唐山大地震后,经过30年的研究和应用,我国相继颁布了一系列有关砌体结构的抗震设计规范,取得了很好的效果。但是我国目前还存在大量未进行抗震设防或抗震设防不足的既有砌体房屋,如何采用合理、有效的方法对这类确体结构房屋进行抗震加固,改善抗震性能,是非常具有社会价值和经济价值的一项研究。
中国、墨西哥、美国、新西兰等大都采用钢筋混凝土构造柱加固砖房。研究成果比较一致地认为,构造柱同圈梁联合使用能有效提高砖结构的延性和变形能力。目前常用的外加构造柱做法主要采用体外增设构造柱并加拉接筋的做法,本文提出的内嵌混凝土构造柱-圈梁加固砌体结构的方法,相比
、“十二五“国家科技支撑计划课题:典型气恢地区既有居住建筑绿色化改造技术研究与工程示范(2012BAJ06B02)
【作者简介】郑吴,高级工程师,国家一级注册结构工程师,E-mail:
zhenghao1973@163.com【收稿日期】2013-04-11
万方数据
其他砌体结构加固方法具有以下优点:①与原结构连接性能可靠,最大限度模拟既有混凝土构造柱-圈梁研体结构房屋:②施工简单,只需对内嵌部位进行施工,涉及面小;③对房屋的外立面及内部使用影响降到最低,具有一定的使用和推广价值。
本次试验研究采用两层两开间1:2的砌体空间结构试验模型,采用内嵌混凝土构造柱-圈梁进行加固,与既有构造柱-圈梁砌体结构模型在水平往复荷载作用下进行对比试验研究,研究加固后砖砌体结构的抗震性能,对加固设计及施工提供技术依据。采用空间结构加固模型可以较好模拟加固构件对结构整体性能的作用,改善单片墙体模型加固试验
的局限性。 2试验方案 2.1试件设计
制作2个两层两开间1:2的空间砌体缩尺模型,其中1个为既有构造柱-圈梁结构,模型编号为 W-1,砌筑砂浆强度为3.08MPa,构造柱与圈梁截面均为120mm×120mm,纵向钢筋均为4Φ10,箍筋均