第44卷第1期
2016年1月【回收与利用】
聚氯乙烯 Polyvinyl Chloride
PVC离心母液水降解处理方法
魏林山,,赵冠民,孙桂元
(云南南磷集团电化有限公司,云南南磷655204)
[关键词】PVC;离心母液水;污水处理;COD;SS
Vol.44,No.1 Jan.,2016
【摘要】介绍了传统污水处理装置处理PVC离心母液水的工艺及工艺控制,采取分流管制、依水配药、综合治理的原则对生产污水进行降解,在无生化床、厌氧池等装置的条件下,将母液水的COD由(180~300)×10*降至50×10"以下;分析了各种母液水处理的影响因素,如SS、环境温度、pH值、流量、反应时间等。
中图分类号】TQ325.3
【文献标志码】B【文章编号】1009-7937(2016)01-003203
DegradationmethodofPCcentrifugalmotherliquor
WEI Linshan,ZHAO Guanmin,SUN Guiyuan
(Yunnan Nanlin Group Electrochemical Co., Ltd.,Nanlin 655204,China)
Key words: PVC; centrifugal mother liquid; sewage treatment; COD; SS
Abstract: Process and process control for the treatment of PVC centrifugal mother liquor by using traditional sewage treatment equipment were introduced. The production wastewater was degraded according to the principle of divided control,addition of reagents in terms of water quality,and comprehensive control. Under the condition without biochemical bed and anaerobic pool, the COD of mother liquor was reduced from (180 300) ×10 ° to less than 50 ×10 "°. The various influence factors of mother liquor treatment, such as SS, ambient temperature, pH value, flow rate, reaction time and so on were analyzed.
云南南磷集团电化有限公司(以下简称南磷电化公司)乙炔发生废水目前全部实现了循环使用,废次氯酸钠清净废水实现了复配使用,含汞废水有单独的处理装置,去离子水和循环水的废水由中水装置处理回用,部分母液水作为冷却水、冲洗水和反应水使用,氯碱装置其他废水水量少、COD低。影响污水COD的主要因素是聚合干燥装置产生的废水,包括离心母液水、汽提废水、涂壁废水,其中涂壁废水、离心母液水对污水的COD影响较大,且水量也较大。离心母液水的COD在(180~350)× 10"而COD更高的涂壁废水则进人乙炔发生废水,不在污水处理之内。南磷电化公司PVC生产装置产能为26万Va,污水处理装置能力为120m/h,
,【收稿日期】2015-03-03
目前实际污水总量约为70m/h。
污水处理工艺
南磷电化公司污水处理装置采用最常规的处理
方法(无生化床及厌氧池等)。聚合于燥装置产生的废水进人调节缓冲池,经调节池缓冲后进人空气氧化池,曝气之后进人反应池,投加相关的污水处理药剂,反应后的水进入沉淀池进行沉降,经沉降处理后进人后期的氧化过滤系统,过滤后污水外排,工艺较为简单、传统。处理废水过程中使用的药剂主要有硫酸亚铁、聚合氯化铝(PAC)、聚丙烯酰胺(PAM)、酸、碱、次氟酸钠、NaHSO,。
整套装置未使用生化床和厌氧池等,也无附
【作者简介】魏林山(1990一),男,助理工程师,毕业于昆明理工大学过程装备与控制工程专业,现于云南南磷集团电
化有限公司从事污水处理、含汞污水处理等公用工程工作。 32
万方数据