燃气技术GasTechnology doi:10.3969/j.issn.16715152.2014.08.004
在建工程旁埋地天然气管道沉降监测实验
口同济大学机械与能源工程学院(201804)肖利涛秦朝葵养业腾
摘要:对在建上海中心工程项目周边的天然气埋地管道进行了沉降监测,发现在监测期间,最
大的正变形量为10mm,最大的负变形量一8mm;对监测结果进行了数值报合和误差分析。
关键词:理地管道沉降监测数值拟合误差分析
ExperimentonSettlementMonitoringofBuriedNatural
GasPipelinenearConstructionProgress
Tongji University, Mechanical and Energy Engineering School, Shanghai
Xiao Litao,Qin Chaokui, Qiao Yeteng
Abstract:The buried natural gas pipelines near the Shanghai tower which was under construction were
monitored and it found that the max positive distortion was 1Omm; the max negative distortion was -8mm.The numerical fitting and error analysis were conducting for the monitoring result.
Keywords:buried pipelinesettlement monitoringnumerical fittingerror analysis
城市天然气管网作为城市天然气输送的重要通道,是城市能源基础设施的重要组成部分。在城市建设快速发展的今天,影响理地天然气管道的不安全因系日益增多,因城市建设引起的地面沉降现象对天然气管道破坏事故屡见不鲜,地面沉降会对地下管道产生破坏,进而导致埋地天然气管道泄漏,威胁生命财产安全[1-2)。
地面沉降的成因主要有溶岩塌陷、地下资源开采和工程环境效应3。随着城市的发展,高层建筑已成为城市地面沉降的主要诱因。国内以上海软土地基为典型的土质地区沉降最为明显,特别是20世纪90年代以来,上海城市建设迅猛发展,在截止2001年的过去
22丨城市燃气2014/08总第474期万方数据
12年中,中心城区平均累计沉降196.7mm,年均沉降 16.4mml4,2008年全市平均地面沉降量为6.4mm,中心城区平均地面沉降则为7.6mm,最大沉降超过10mm 的地区也多有发生15。敷设在软体地基中的管道因沉降会产生各种变形,均勾沉降对管道影响不大,当发生不均勾沉降时,管道就有可能发生变形甚至破环。高层建筑引起的地面沉降必定会对周围燃气管道产生影响,使管道受到附加的压力和水平推力,产生形变和位移,导致管道变形、接口错位甚至腐蚀开裂,造成燃气泄漏。研究高层建筑导致的地面沉降对埋地天然气管道的影响,进而建立相应的预警机制和预防措施具有十分重要的意义。