2012年第6卷第2期 2012,Vol.6,No.2
南方电网技术
SOUTHERN POWER SYSTEM TECHNOLOGY
文章编号:1674-0629 (2012)02-0062-04
中图分类号:TM401.2
系统运行与管理
System Operation & Management
文献标志码:A
110kV及以上变压器(电抗器)状态评估方法及案例
钟顺帆,万金萍,石延辉,谢超
(中国南方电网超高压输电公司广州局,广州510663)
摘要:介绍变压器状态评估方法,并分析了南方电网某局对其所薪的5个变电站(模流站)的110kV及以上的变压器(电抗器)开展状态评估的案例。该案例参考了各个状态量进行综合评分,评估出变压器的状态等级,结累有参考价值,
但评估方法中对不同状态量进行人工打分的做法受人为因素影响较大。关键词:电力变压器;电抗器;状态评估;状态检修
TheConditionAssessmentMethodandCaseAnalysisof11okVandAbove
Transformers/Reactors
ZHONG Shunfan, WAN Jinping, SHI Yanhui, XIE Chao
(Guangzhou Bureau, CSG EHV Power Transmission Company, Guangzhou 510663, China)
Abstract: The condition assessment method of ransformers/reactors is introduced with a case analysis of 11o kV and abovc transformers/reactors in the five substations/converter stations of China Southem Power Grid. In the case analysis, the condition rank of the transformers/reactors is given according to the comprehensive evaluation of various condition variables, and the results are of
reference. The evaluation method, however, is to be improved as it adopts artificial scording in the condition variable evaluation Key words: transformer; reactor; condition assessment; condition-maintenance
长期以来,电力公司对变压器的检修往往放在故障之后,用故障前后特征量的变化进行故障诊断,并结合预防性试验来诊断变压器是否存在潜伏性故障。定期检修的模式一定程度上能消除隐患,预防事故的发生,但是每年定期的大修不仅消耗大量物资,更重要的是设备拆合频繁也是一种磨损,给设备也带来一定的隐患。
状态评估是对变压器的运行状态及其他信息进行记录、分类和评估,为设备维修提供决策。按状态评估的要求,2011年4月南方电网某局对其所辖的 A换流站、B换流站、C换流站、D变电站及E换流站110kV及以上的变压器(电抗器)全面开展状态评估。
1国内外变压器状态评估研究与应用情况
目前,国内外对变压器状态评估中的故障诊断研究较多。常用以溶解气体分析为主结合其他电气试验结果的综合诊断方法对变压器进行故障诊断,如IEC三比值法。日本电气协同研究会提出的电协研法和我国湖北电力试验研究所提出的改良电协研
法。这些方法大多局限于阅值诊断的范畴]。
近年来,各种智能技术如人工神经网络、概率推理、判决树、信息融合、Petri网络等被引入变压器故障诊断中,取得了较好的效果,
在故障预测方面,经常应用神经网络法预测变压器油的介质损耗因数,从而预测变压器油的热老化故障和以灰色系统理论为基础,研究了电气绝缘故障诊断的灰色预测模型新模式及其应用。
然而,这些故障诊断和预测方法都是基于某一因素或某儿个因素去做出判断,并未全面综合考虑变压器的运行工况、预试状态、缺陷、检修、家族质量史、在线检测等状态信息。且对变压器的状态进行评估时,大部分研究着重于评价变压器的现有状况。
变压器状态评估内容和方法 2
变压器状态评估的内容
2.1
变压器状态评估是电力变压器状态检修的基础工作,其目的在于对变压器展开故障预测和故障诊断。无论是变压器敌障诊断还是故障预测,都需要