56
燃料与化工 Fuel & Chemical Processcs
洗苯塔阻力增大的原因与治理
王敬坡’赵洪液’王玉龙?
(1.河北钢铁集团邯钢矿业分公司,邯郸
5056201;
2.河北钢铁集团邯钢丰达冶金原料有限公司,邯郸
056201)
Jan.2017 Vol. 48 No.1
摘要:通过对洗苯塔内堵塞情况检查以及对油垢检测,分析了堵塞物形成的原因,制定了控制措施。探索了用药
剂进行化学清洗的方法,取得了明显效果,阻力下降了2500Pa,粗苯收率提高了0.15%。关键词:洗苯塔;阻力;堵塞;清洗
中图分类号:TQ522.53
文献标识码:A
文章编号:10013709(2017)01-005603
Reasonfortheincreasingresistanceincrudebenzol
scrubber and measures Wang Jingpo'Zhao Hongbo*Wang Yulong
(1. Handan Mining Branch of Hebei Iron & Steel Croup,Handan 056201,China;
2. Handan Fengda Metallurgical Raw Material Company of Hebei Iron & Steel Group,Handan 056201,China)
Abstract: The reason for the formation of blockage is analyzed based on the inspection of the crude benzol scrubber and test of greasy stain, and corresponding measures are taken. The method of cleaning with chemical agents is effective. The resistance of the crude benzol scrubber is reduced by
2 500Pa,and the recovery rate of crude benzol is increased by 0. 15%. Key words: Crude benzol scrubber; Resistance; Blockage; Cleaning
邯钢丰达公司有2座TJL4350D型63孔固焦炉,于2006年1月投产,年产焦炭80万t,煤气流量 32000~45000m/h。开工后,洗苯塔正常状态下阻力为1500Pa左右,塔后煤气含苯2.5g/m,达到了设计要求。从2013年阻力逐渐上升,至2014年 2月洗苯塔阻力达3000Pa左右,开始对生产有影响,至2014年9月,洗苯塔阻力上升到6200Pa,塔后煤气含苯也升高到5.4g/m"。为降低阻力,多次采取热贫油喷酒洗塔、蒸汽吹扫、全面置换系统洗油和清理油槽油垢等措施,但保持时间短,阻力增长比较快,一般2周内会增加到清洗前的水平。
1堵塞情况与垢样分析 1.1
阻力分布及塔内堵塞现状
生产运行过程中,对洗苯塔分段测压,其阻力分布情况如下:捕雾层800Pa、1段1800Pa、2~3段收稿日期:2016-05-16
作者简介:王敬坡(1975-),男,工程师万方数据
2500Pa、4段1100Pa。利用停工时间,打开4个人孔检查各段填料层及层间液体分布器,从外观看1 段填料表面结晶物多,在人孔处大量堆积,填料支撑板已糊满油垢,填料表面油层有乳化现象;液体分布器内油垢沉积较多;2~4段填料侧面和流道堵塞严重。启动泵观察液体喷淋情况,发现各层间存在偏
流,2~3层偏流严重。 1.2垢样分析
停工后从塔内填料表层取样进行分析,发现该垢样在25℃时很黏稠、不流动,有明显的长颗粒状结晶。
使用二氯甲烷对垢样进行溶解分析,可溶部分为30%,不溶物70%。FTIR分析显示可溶部分主要为芳烃,不溶物中主要成分为硫氰酸根,同时有痕量的铵盐。对垢样进行元素分析,二氯甲烷不溶物中的元索组成为碳19%,氢3%,氮26%,硫9%。对垢样进行灼烧减量分析,烧损为77%,烧损部分