54 其它
东北电力技术
NORTHEAST ELECTRIC POWER TECHNOLOGY
2014年第6期
AP1000核电站辅助变压器制造工艺及监造要点浅析
李岩
(中核集团三门核电有限公司,浙江三门317112)
摘要:辅助变压器为核电站重要的备用电源,辅助变压器的可靠运行为机组稳定运行提供有力保证,AP1000核电站辅助变压器为分裂变,容量和电流较大,有一定制造难度。主要介绍AP1000核电站辅助变压器的制造工艺,以及辅
助变压器监造过程中需要注意的重点,并对制造过程中可能出现的缺陷提出防治措施。关键词:辅助变压器;制造工艺;监造
[中图分类号]TM623[文献标志码]】A[文章编号]10047913(2014)06-0054-05
Analysis on Manufacturing Process and Superivision ofAP1oooNuclearPowerStationAuxiliaryTransformer
LIYan
(CNNC Sanmen Nuclear Power Company, Sanmen, Zhejiang 317112, China)
Abstract: Auxiliary transfomer is an important emergency power supply for nuclear power plant.To guarantee the stable operation of the unit, it is hoped the auxiliary transformer can run reliably. The auxiliary transformer of AP1000 nuclear power plant is a split transformer, capacity and current of which is big, which is difficult in manufacturing. This article introduces the manufacturing process of the auxiliary transformers, summarizes some key points that needs to pay attention to, In addition, it puts forward preven tive measures for the possible defects in the manufacutring process.
Key words: Auxiliary transformers; Manufacturing process; Supervision
三门核电站有一路单独的220kV备用电源,辅助变压器将备用电源的220kV电压转换为10.5 kV,供给厂用中压负荷。当厂用变压器和550kV 线路失电后,将启用备用220kV电源,220kV架空线通过252kV屋内GIS经220kV电缆与辅助变联接[2],辅助变的稳定运行,保证了电站的备用电源安全可靠。本文主要介绍辅助变压器的制造工艺和监造重点,对变压器的工厂监造有一定借鉴意义。三门核电辅助变压器高压侧电压等级为220 kV,容量较大,电流较大,因此在整个制造中需进行严格的监造和检查,以保证辅助变压器的质量。
辅助变压器简介 1
1.1变压器主要参数
三门辅助变压器额定容量为88/44-44MVA,额定电压为231(+4~-12)×1.25%kV/10.5 kV,高压侧有载调压,额定电流高压侧220A(线电流),低压侧2420A(线电流)。中性点接地方万方数据
式:高压侧直接接地,低压侧经低电阻接地。 1.2高压和低压绕组
如图1、图2,高压绕组采用纠结连续型绕制,低压绕组为双U型线圈。高压绕组线规2×2.1x 9.6,低压绕组采用ZB-0.3/1.35。电压组合为
231 (+4~12)×1.25% kV/10.5/10.5。 1.3变压器铁心
铁心的磁导体是变压器的磁路。它把一次电路的电能转化为磁能,又由自已的磁能转化为二次电路的电能,是能量转化的媒介。三门核电辅助变压器为叠铁心,且为搭接形式,各接缝错开压住,可以避免发生片间短路间题,并且机械性能。铁心由铁心叠片、绝缘件和铁心结构件等组成。而铁心结构件又由夹件垫脚、撑板、拉板、压钉等组成。结构件保证叠片的充分夹紧,形成完整而牢固的铁心结构。叠片与夹件、垫脚、撑板、拉带和拉板之间均有绝缘件。铁心叠片及夹件接地引出线通过油箱到外部可靠接地,铁心只允许一点接地3)(见图 3)。