上海节能
630MW超临界机组锅炉及其辅助系统节能诊断
彭志福
大唐华东电力试验研究院
o.59 2018
摘要:通过对某电厂630MW的机组锅炉进行节能诊断,在对该机组锅炉侧节能潜力进行分析的同时对锅炉侧各项指标与设计值进行对标,并对锅炉的运行及设备所存在的问题进行分析,查找影响机组运行经济性的原因,从设备和运行调整方面提出节能降耗的措施。
关键词:锅炉:节能诊断;节能潜力
DOl:10.13770/j.cnki.issn2095-705x.2018.09.015
EnergySavingDiagnosisof63oMwSupercriticalUnit
BoilerandItsAuxiliary System PengZhifu
Datang East China Electric PowerTest and Research Institute
Abstract:The energy saving diagnosis of 63oMw boiler in a power plant is carried out.The energy saving potential of the boiler side is analyzed.Each side of the boiler side is matched with the design value.And analysis of boiler operation and equipment problems.Find out the reasons that affect the op-erating economy of the unit,The measures for saving energy and reducing consumption are put forward fortheunitfromtheaspectsofequipmentandoperationadjustment
Keywords:Boiler,EnergySavingDiagnosis,EnergySavingPotential
根据国务院印发《“十三五”节能减排综合工作方案》},到2020年火电供平均电煤耗要达 306g/kWh,因此火电的节能工作日益重要。某电厂共4台机组,其中1号机组及2号机组能耗指标较好,但3号机组煤耗明显高于其他几台机组,问题突出。为评估该电厂3号机组的能耗状况(2),对该机组锅炉及其辅助系统进行节能诊断,找出锅炉及其
」节能技术与产品 738
ENERGYCONSERVATIONTECHNOLOGIESAND PRODUCTS 万方数据
辅助系统的问题,并给出建议措施。 1锅炉概述
该机组选用哈尔滨锅炉有限责任公司与三井巴布科克(MB)公司合作设计制造的超临界本生(Benson)直流锅炉,型号:HG-1890/25.4-YM4。一次中间再热、滑压运行,锅炉配置再循环泵启动