总第246期 2016年第6期
河北冶金 HEBEI METALLURGY
斯太尔摩辊道风机超频提速的应用
王晓东,宋召勇,刘维
(邢台钢铁有限责任公司,河北邢台054027)
Total No.246 2016,Number6
摘要:为解决夏季生产预应力钢线材抗拉强度低的问题,对斯太尔摩辊道风机的使用现状进行了分析。通过对风机的超频提速,降低了环境温度对线材抗拉强度指标的影响,增加了预应力钢的索氏体组织比例,抗拉强度提高47MPa,达到了用户的使用要求。但风机超频提速后,必须增加维护的频次,防止风机
烧损。冬季生产时,线材的冷却速度过快,需要预防出现马氏体等有害组织。关键词:斯太尔摩辊道:风机;超频;提速;应用
中图分类号:TG333.2
文献标识码:B
doi;10.13630/j. cnki.13 1172.2016.0614
文章编号:10065008(2016)06005603
APPLICATIONOFSTELMOR
ROLLTABLEFANOVERCLOCKINGSPEEDUP
Wang Xiaodong,Song Zhaoyong,Liu Wei
(Xingtai Iron and Steel Co. , Lid. , Xingtai, Hebei, 054027)
Abstract: To solve the problem of low tensile strength of pre stressed steel wire produced in summer, the present operation status of Stelmor roll table fan is analyzed. With over clocking speed up of the fan, the influence of environment temperature on the wire tensile strength index is reduced, the ratio of sorbite structure in pre stressed steel raised, its tensile strength increased by 47 MPa, reached the demand of customers. But to prevent the fan burned, its maintenance must be strengthened. In winter, because of too
fast cooling, the harmful structure such as martensite must be prevent for the wire. Key Words : Stelmor roll table; fan; over clocking: speed up; application
0
引言
邢钢线材厂五车间是精品钢生产车间,主要承担高强度预应力钢(如SWRS82B、SWRS87B、U183 等)线材的生产。产品检验结果表明:自前五车间的控冷风机冷却能力不足,造成大批量不合格产品出现,并且影响了以后更高强度级别产品的开发,为此提出了风机改进的建议。
斯太尔摩辊道风机使用现状
目前,预应力钢抗拉强度低的问题主要表现在,第一,线材的实际强度控制范围位于用户要求的偏下限区域,容易出现不合格产品:第二,线材的强度受季节影响明显,在夏季明显的降低。斯太尔摩辑道控冷风机用于线材终轧后的快速冷却,其冷却能
收稿日期:2016-04-22
作者简介:王晓东(1975-),男,工程师,2000年毕业于北京理工大学机电一体化工程专业,现在邢台销铁有限责任公司公司从事工程
管理工作,Email:15100962602@163.com 56
力大小,直接影响到预应力钢抗拉强度的高低[] 预应力钢要求吐丝后,通过辊道吹风急冷使线材温度降低到550℃发生相变,以得到强度高、有利于拉拨的索氏体组织。随着高强度预应力钢的开发,对
辊道风机的冷却能力提出了越来越高的要求。 1.1环境温度的影响
由于现有斯太尔摩控冷是以空气作为冷却介质,环境温度不可避免地影响线材的强度。图1、图 2是五车间生产H82B钢Φ12.5mm线材月平均抗拉强度曲线,由此可以明显看出季节对线材强度的影响趋势:在夏季气温升高时,抗拉强度大幅度降低,而冬季气温低时抗拉强度升高。