NB/T 10282-2019
交流无间隙金属氧化物避雷器试验导则
Guide to the interpretation of metal-oxide surge arresters without gaps for alternating-current systems(Guide to the IEC 60099-4)
2020-05-01实施
2019-11-04发布
目 次
前言 ...............................................................................1
1 概述 .............................................................................. 1
2 规范性引用文件 .................................................................... 1
3 术语和定义 ........................................................................ 1
3.1 同族系列避雷器 ................................................................ 1
4 避雷器信息 ........................................................................ 1
4.1 瓷外套避雷器及复合外套避雷器 .................................................. 1
4.2 气体绝缘金属封闭(GIS)避雷器 ................................................. 4
4.3 分离式及外壳不带电避雷器 ...................................................... 5
5 避雷器型式试验 .................................................................... 6
5.1 瓷外套避雷器和复合外套避雷器型式试验报告分类及试验项目 ........................ 6
5.2 气体绝缘金属封闭(GIS)避雷器型式试验报告分类及试验项目 ....................... 9
5.3 分离式及终端避雷器型式试验报告分类及试验项目 ................................. 10
6 同族系列避雷器 ................................................................... 11
附录 A(规范性附录) GB/T 11032-XXXX 中部分章节的说明 .............................. 14
附录 B(规范性附录) 重复转移电荷耐受试验中重复电荷校正系数计算的示例 ............... 16
附录 C(资料性附录) GB/T 11032-XXXX 附录 C 中补偿温度计算的示例 .................... 18
附录 D(资料性附录) 典型的同族系列避雷器示例....................................... 22
前 言
本标准按照GB/T 1.1-2009给出的规则起草。
本标准修改采用“STL导则—IEC 60099-4 Edition 3.0 2014-06”。
本标准与“STL导则—IEC 60099-4 Edition 3.0 2014-06”的差异相比,主要技术性差异如下:
——增补了我国国内习惯使用,而“STL导则—IEC 60099-4 Edition 3.0 2014-06”中未包含的试验内容,如:直流参考电压试验,0.75倍直流参考电压下漏电流试验等;
——使用范围增加了分离式及外壳不带电避雷器。
本标准由中国电器工业协会提出。
本标准由能源行业短路试验技术标准化技术委员会(NEA/TC10)归口。