Q/GDW 11835-2018
12kV~40.5kV交流金属封闭开关设备局部放电试验导则
Guide for partial discharge testing of alternating-current metal-enclosed switchgear for rated voltages above 12kV and up to and including 40.5kV
2019-07-31实施
2019-07-31发布
目 次
前 言................................…..….…........................................1
1 范围............................................................................1
2 规范性引用文件....................................................................1
3 术语和定义........................................................................1
4 试验回路和测量系统.........................................................1
5 试验方法及程序....................................................3
6 试验判据........................................................................4
7 外部干扰抑制....................................................5
附录A(资料性附录) 弧光接地过电压水平.....................................7
附录B(资料性附录) 开关柜局部放电试验记录格式......................................9
编制说明....................................................................................................................10
前 言
为规范12kV~40.5kV开关柜局部放电试验要求,提高12kV~40.5kV开关柜运行可靠性,指导设备管理人员和现场工作人员开展开关柜局部放电试验,以发现设备绝缘缺陷和异常情况,制定本标准。
本标准由国家电网有限公司设备管理部提出并解释。
本标准由国家电网有限公司科技部归口。