Q/GDW 1152.1-2014代替Q/GDV 152—2006
电力系统污区分级与外绝缘选择标准第1部分 交流系统
Pollution classification and external insulation selection for electric power systemPart 1:a.c. system
2015-02-26实施
2015-02-26发布
目 次
1范围..............................................................................................1
2 规范性引用文件.......................................................................................1
3 定义和术语....................................................................................1
4 污秽种类、环境类型及现场污秽度.................................................2
5 污秘度评估.......................................................................................................4
6 外绝缘选择................ .........................................................................6
附录A(规范性附录) 等值附盐密度( ESDD ) 和灰密( NSDD ) 的测量方法...….10
附录B(规范性附录) B类污秽的评估...........................................................16
附录C(资料性附录) 复合绝缘子现场污秽度与等值盐密/灰密的关系............17
附录D(资料性附录) 双伞型盘形绝缘子现场污秽度与等值盐密/灰密的关系..........18
附录E(规范性附录)污秽外绝缘配置的基本原则和方法...........................19
附录F(资料性附录) 污秽地区绝缘子积污状况调查表示例.................20
附录G(资料性附录)运行经验...............................................23
编制说明.............................................................................................25
1 范围
本标准包括电力系统污秽等级的划分和不同污区的基本绝缘配置两部分,不对绝缘子材料和伞型参数进讲行认定。本标准的主要目的是提出;(①表征自然环境的污湿特征和交流绝缘子的现场污秽度。②确定各交流电压等级常用绝缘子的绝缘配置(包括线路绝缘子片数和站用支柱绝缘子的绝缘长度与爬电距离)。
本标准适用于额定电压 110(66)kV~1000kV三相交流电力系统中架空线路和变电站(含发电厂、开关站、换流站交流场)户外设备外绝缘。其中不包括避雷器和敞开式断路器的断口绝缘。
本标准不涉及海拔、覆冰、覆雪、大雨及覆雪对污秽绝缘子的影响。
2 规范性引用文件
下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注明日期的引用文件,其随后所有的修改(不包括勘误的内容)或修订版均不适应于本标准,然而,鼓励根据本标准达成协议的各方面研究是否可使用这些文件的最新版本。凡是不注明日期的引用文件,其最新版本适用于本标准。