HJ 101-2019 代替 HI/T 101-2003
氨氮水质在线自动监测仪技术要求及检测方法
Technical specifications and test procedures for water quality on-line automatic monitoring equipment of ammonia (发布稿) 本电子版为发布稿。请以中国环境出版集团出版的正式标准文本为准。
2020-03-24实施
2019-12-24发布
目 次
前言...............................................................................................................................................1
1适用范围.....................................................................................................................................1
2规范性引用文件.........................................................................................................................1
3术语和定义.................................................................................................................................1
4技术要求.....................................................................................................................................3
5性能指标及检测方法.................................................................................................................5
6操作说明书...............................................................................................................................12
前 言
为贯彻《中华人民共和国环境保护法》和《中华人民共和国水污染防治法》,保护生态环境,保障人体健康,规范氨氮水质在线自动监测仪的技术性能,制定本标准。本标准规定了氨氮水质在线自动监测仪的技术要求、性能指标及检测方法。本标准是对《氨氮水质自动分析仪技术要求》(HJ/T101-2003)的修订。
本标准首次发布于2003年,原标准起草单位为中国环境监测总站,本次为首次修订。本次修订的主要内容如下:
——名称修改为《氨氮水质在线自动监测仪技术要求及检测方法》
——增加仪器的检测范围,区分检测范围与仪器量程范围;
——增加示值误差、定量下限、记忆效应、电压影响试验、pH影响试验、环境温度影响试验、有效数据率、最小维护周期、一致性等性能指标;
——删除仪器原理要求,不区分电极法与光度法,删除相应的响应时间指标:——修改了零点漂移、量程漂移、重复性和实际水样比对试验等性能指标。
自本标准实施之日起,《氨氮水质自动分析仪技术要求》(HJT101-2003)废止。本标准由生态环境部生态环境监测司、法规与标准司组织制订。
本标准主要起草单位:中国环境监测总站。