GB/T 18890.1—2015
额定电压220 kV(Um = 252 kV)交联 聚乙烯绝缘电力电缆及其附件
第1部分:试验方法和要求
Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV(U„ = 252 kV)_Part 1: Test methods and requirements 2015-10-09 发布
2016-05-01 实施
GB/T 18890.1—2015
目录
1范围........................................1
2规范性引用文件...................................1
3术,和定义.....................................2
4电压标示和材料................................ 3
5电缆阻水措施....................................4
6电缆特性.................................... 4
7附件特性.................................... 5
8试验条件......................................5
9电缆和预制附件主绝缘的例行试验 ......................... 6
10电缆的抽样试验................................. 7
11附件的抽样试验 ................................10
12电缆系统的型式试验 ..............................11
13电缆系统的预鉴定试验 .............................21
14电缆的型式试验 ................................24
15附件的型式试验 ................................24
16安装后的电气试验 ...............................24
附录A (资料性附录)电缆导体温度的测定......................26
附录B (规范性附录)数值修约...........................30
附录C (资料性附录)电缆系统的型式试验、预鉴定试验和预婆定扩展试验一览表.....31
附录D (规范性附录)半导电屏蔽电阻率测量方法...................33
附录E (规范性附录)透水试验...........................35
附录F (规范性附录)具有与外护套黏结的纵包金属带或纵包金属精的电缆组件的试验....37
附录G (规范性附录)接头的外保护层试验......................39
附录H (规范性附录)微孔、杂质与半导电屏蔽层界面突起试验.............41
附录I (资料性附录)本部分与IEC 62067:2011相比的结构变化情况....43
附录J (资料性附录)本部分与IEC 62067,2011的技术性差异及其原因...44
参考文献......................................46